Examine the Online Catalog of Industrial Supplies for AirCom Pneumatic
Great Offers at Unbeatable Prices
Extensive Selection
Quick Shipping
Sale of any product from the catalog AirCom Pneumatic
Brand name
AirCom Pneumatic
Article
MKA-C2
Country
Germany
tpl10.product.param.weight
350
part number: | MKA-C2 |
overpressure max. [bar]: | 0,75 |
input signal: | - |
pressure range [bar]: | - |
pressure range [mbar]: | 0...250 |
output signal [V]: | 0-10 |
repeatability [%]: | 0,1 |
temperature sensitivity [%]: | 1,0 |
linearity deviation [%]: | 0,5 |
Suitable for measurement of positive pressure, vacuum or
differential pressure.
Media: compressed air or non-corrosive gases
Overpressure: see chart
Supply_voltage: 15...30 V DC standard, optionally 230 V AC ± 10%
Electrical_connector: plug with 7-pin screw terminal for cable
cross-sectional area 0.14...1.5 mm²
Pneumatic_connection:
P+: pos. pressure
P-: vacuum
P+/P-: differential pressure, the higher pressure is to
be connected at P+;
plug nipple up to 1 bar, sleeve with union nut from 2 bar on,
each for hose internal diameter of Ø 4 mm
Display:
31/2-digit LCD display, max. ± 1999, 14 mm tall, black numbers
red LED lights up at overpressure, then measurement is faulty
Output_signal:
0...10 V, impedance > 10 kΩ,
optionally 4...20 mA, impedance < 500 Ω
Linearity: see chart, optionally 0.2% FS
Hysteresis: < 0.1% FS
Long-term_stability:
< 0.1% FS per year at > 25 mbar,
< 1.0% FS per year at > 5 mbar,
< 2.0% FS per year at < 5 mbar range
Temperature_sensitivity: see chart, at 0 to 50 °C / 32 to 122 °F
Repeatability: see chart
Response_time: 100 ms
Resolution: 1 digit
Protection_class: IP 54
Temperature_range: -20 °C to 50 °C / -4 °F to 122 °F
Housing: aluminium
differential pressure.
Media: compressed air or non-corrosive gases
Overpressure: see chart
Supply_voltage: 15...30 V DC standard, optionally 230 V AC ± 10%
Electrical_connector: plug with 7-pin screw terminal for cable
cross-sectional area 0.14...1.5 mm²
Pneumatic_connection:
P+: pos. pressure
P-: vacuum
P+/P-: differential pressure, the higher pressure is to
be connected at P+;
plug nipple up to 1 bar, sleeve with union nut from 2 bar on,
each for hose internal diameter of Ø 4 mm
Display:
31/2-digit LCD display, max. ± 1999, 14 mm tall, black numbers
red LED lights up at overpressure, then measurement is faulty
Output_signal:
0...10 V, impedance > 10 kΩ,
optionally 4...20 mA, impedance < 500 Ω
Linearity: see chart, optionally 0.2% FS
Hysteresis: < 0.1% FS
Long-term_stability:
< 0.1% FS per year at > 25 mbar,
< 1.0% FS per year at > 5 mbar,
< 2.0% FS per year at < 5 mbar range
Temperature_sensitivity: see chart, at 0 to 50 °C / 32 to 122 °F
Repeatability: see chart
Response_time: 100 ms
Resolution: 1 digit
Protection_class: IP 54
Temperature_range: -20 °C to 50 °C / -4 °F to 122 °F
Housing: aluminium
- Delivery of spare parts and industrial equipment throughout the USA by Fedex transport company.
- Flexible payment system accepting bank transfers, MasterCard, VISA, PayPall, App Pay, Google Pay.
- Directly from stock and on order.