Examine the Online Catalog of Industrial Supplies for COMITRONIC-BTI
Level of performance without an external controller
|
PL = d
|
Level of performance with AWAX controller
|
up to PL = e
|
Safety category without an external controller
|
3
|
Safety Integrity Level
|
SIL2
|
Cycle after dangerous failure
|
B10d = 2,000,000 at 2A
|
Max. activation distance
|
10 mm, 2 mm hysteresis
|
Security contacts / diagnostics
|
AMX5 / AMX5CM12 : 2 x NO 2A / 48V redundant / 1 x PNP 250mA auxiliary |
Security contacts AMX4
|
2 x NO 2A/48V redundant
|
Security contacts / diagnostics AMX3
|
1xNO 2A / 48V redundant (2 series contacts) / 1xNF 250mA auxiliary
|
Detection encoding |
mono-code inviolable
|
Indicator |
LED indicates code recognition
|
Reset |
automatic
|
Attachment |
4 tamper-proof M4 screws (optional ref: BH4)
|
Mounting position |
2 (double wall brackets)
|
Material |
PA6 or INOX 316L mirror polished (AMX3-OX/AMX5-OX or PC (AMX5CM12)
|
Electrical Connection |
3, 6, 12m (UL2464 PVC) or 50cm cable with M12 connector (UL20549 PUR) (ref + MKT) or M12 metal base (AMX5CM12)
|
Water resistance |
IP 68 (PA6) or IP 69K with stainless steel - new generation
|
Temperature |
-25°C to +60°C
|
Marking |
PA6 pad printing + serial number, INOX316L laser engraving with mechanically punched serial number for permanent traceability
|
Certification |
TÜV Rheinland 01/205/5238/12
|
License Test |
Mark 968/EL 214.01/12
|
Controls the position of hazardous machine doors/cases with integrated self-checking Contactless coded sensor with electronic technology and relays IP68 PA6 / IP69K INOX316L Performance level and category without external controller: Cat 3 PL=d according to ISO 13849-1 Performance level and category with AWAX controller: Cat 4 up to PL=e Integrated safety level: SIL 2 according to IEC 61508
Level of performance without an external controller: PL = d
Level of performance with AWAX controller: up to PL = e
Safety category without an external controller: 3
Safety Integrity Level: SIL 2
Cycle after dangerous failure: B10d = 2,000,000 at 2A
Max. activation distance: 10 mm, 2 mm hysteresis
Security contacts / diagnostics AMX5 / AMX5CM12 : 2 x NO 2A / 48V redundant / 1 x PNP 250mA auxiliary
Security contacts AMX4: 2 x NO 2A/48V redundant
Security contacts / diagnostics AMX3 : 1xNO 2A / 48V redundant (2 series contacts) / 1xNF 250mA auxiliary
Detection encoding: mono-code inviolable
Indicator: LED indicates code recognition
Reset: automatic
Attachment: 4 tamper-proof M4 screws (optional ref: BH4)
Mounting position: 2 (double wall brackets)
Material: PA6 or INOX 316L mirror polished (AMX3-OX/AMX5-OX ?or PC (AMX5CM12)
Electrical Connection: 3, 6, 12m (UL2464 PVC) or 50cm cable with M12 connector (UL20549 PUR) (ref + MKT) or M12 metal base (AMX5CM12)
Water resistance: IP 68 (PA6) or IP 69K with stainless steel - new generation
Temperature: -25°C to +60°C
Marking: PA6 pad printing + serial number, INOX316L laser engraving with mechanically punched serial number for permanent traceability
Certification: TÜV Rheinland 01/205/5238/12
License Test Mark 968/EL 214.01/12
- Delivery of spare parts and industrial equipment throughout the USA by Fedex transport company.
- Flexible payment system accepting bank transfers, MasterCard, VISA, PayPall, App Pay, Google Pay.
- Directly from stock and on order.