Supply of spare parts for industrial enterprises in the USA

Emirel GC 08

Generator GC 08 Emirel

Examine the Online Catalog of Industrial Supplies for Emirel


Great Offers at Unbeatable Prices
Great Offers at Unbeatable Prices
Discover incredible savings on industrial spare parts and components
Extensive Selection
Extensive Selection
Explore a wide variety of industrial spare parts to find the ideal fit for your needs
Quick Shipping
Quick Shipping
Get your industrial parts delivered promptly—right to your door!
Sale of any product from the catalog Emirel
Brand name
Emirel
tpl10.product.param.model
GC 08
Country
Italy
tpl10.product.param.purpose
Generator
NUMBER OF THE OUTPUTS: from 1 to 32 (extensible to 64), to be specified at the order (set during the test procedure). I: (PULSE) adjustment by screwdriver for the pulse period: from 40ms to 1 second (Tab. A). The pulse activation is pointed out by the lighting of the red led correspondent to each output. P: (PAUSE) adjustment by screwdriver for the pause period: between one pulse and the next one (Tab. A). When 1-DS3 is OFF the adjustment ranges from 1s to 60s. When 1-DS3 is ON the period is multiplied by 10. The pause is pointed out by the green led P. CPL Number of post cleaning cycles; each tick mark of the index corresponds to approximately 10 cycles. Adjustment by screwdriver (Tab. C) to set the number of cycles to be performed after the cyclic device has been switched off (contact start opened) and the post cleaning contact is opened. If this regulation is set to 0 the post cleaning does not take place, even if the contact post cleaning is opened. (during the Post Cleaning Operation the device must be supplied). The post cleaning takes place only if “CPL” is set outside the tick-mark “0” (slightly towards 1) and when the turbofan ventilator is open (green led ABIL turns off, and the yellow led of post-cleaning PL turns on). The pause period durin DEVICE SUPPLY pins 65-66 3VA 50÷60Hz 24Vac or 115 Vac or 230 Vac LOAD SUPPLY pins A1-A2 24Vac÷230 Vac or 24 Vdc g the post cleaning is set by the regulation P “pause”. CASE plastic with transparent cover IP 56 (fig.5 and6) M100: n° 4 wall fixing plates Model from 2 to 32 outputs size 250x246x95 mm fig. 5. Model from 33 to 64 outputs size 507x246x95mm fig. 6. WEIGHT 2 Kg approx ( 2 to 32 outputs). 3 Kg approx (33 to 64 outputs).
FUNCTION The device energizes the outputs in sequence for the period I (PULSE). Between the excitation of two outputs the period P (PAUSE) takes place. After the last output, the first one is energized again, and a new cycle starts. USE It is used for the cyclic command of several loads, such as electrovalves for filters, contactors, relays, lamps, for the gradual connection of loads etc. In the applications with sleeve-filters the period I is used to energize electrovalves issuing a compressed air jet (5÷6 bar) shaking the sleeve of the filter.
  • Delivery of spare parts and industrial equipment throughout the USA by Fedex transport company.
  • Flexible payment system accepting bank transfers, MasterCard, VISA, PayPall, App Pay, Google Pay.
  • Directly from stock and on order.