tpl10.product.param.model
GC 08
Country
Italy
tpl10.product.param.purpose
Generator
NUMBER OF THE OUTPUTS: from 1 to 32 (extensible to
64), to be specified at the order (set during the test
procedure).
I: (PULSE) adjustment by screwdriver for the pulse period:
from 40ms to 1 second (Tab. A). The pulse activation is
pointed out by the lighting of the red led correspondent to
each output.
P: (PAUSE) adjustment by screwdriver for the pause period:
between one pulse and the next one (Tab. A). When 1-DS3
is OFF the adjustment ranges from 1s to 60s. When 1-DS3
is ON the period is multiplied by 10. The pause is pointed
out by the green led P.
CPL
Number of post cleaning cycles; each tick mark of the index
corresponds to approximately 10 cycles. Adjustment by
screwdriver (Tab. C) to set the number of cycles to be
performed after the cyclic device has been switched off
(contact start opened) and the post cleaning contact is
opened. If this regulation is set to 0 the post cleaning does
not take place, even if the contact post cleaning is opened.
(during the Post Cleaning Operation the device must be
supplied). The post cleaning takes place only if “CPL” is set
outside the tick-mark “0” (slightly towards 1) and when the
turbofan ventilator is open (green led ABIL turns off, and the
yellow led of post-cleaning PL turns on).
The pause period durin
DEVICE SUPPLY
pins 65-66 3VA 50÷60Hz 24Vac or 115 Vac or 230 Vac
LOAD SUPPLY
pins A1-A2 24Vac÷230 Vac or 24 Vdc g the post cleaning is set by the
regulation P “pause”.
CASE
plastic with transparent cover IP 56 (fig.5 and6)
M100: n° 4 wall fixing plates
Model from 2 to 32 outputs size 250x246x95 mm fig. 5.
Model from 33 to 64 outputs size 507x246x95mm fig. 6.
WEIGHT
2 Kg approx ( 2 to 32 outputs).
3 Kg approx (33 to 64 outputs).
FUNCTION
The device energizes the outputs in sequence for the period
I (PULSE). Between the excitation of two outputs the period
P (PAUSE) takes place. After the last output, the first one is
energized again, and a new cycle starts.
USE
It is used for the cyclic command of several loads, such as
electrovalves for filters, contactors, relays, lamps, for the
gradual connection of loads etc.
In the applications with sleeve-filters the period I is used to
energize electrovalves issuing a compressed air jet (5÷6
bar) shaking the sleeve of the filter.