Brand name
Emirel
tpl10.product.param.model
RV6
Country
Italy
tpl10.product.param.purpose
Voltage relay
REGULATIONS AND GENERAL
FEATURES (fig. 4,5)
SP1
Max set point, adjustable by means of
screwdriver. The scale is divided in 10
parts. The value of each part
corresponds to 1/10 of the full scale FS.
SP2
Set point adjustable by screwdriver as
max or min power set point. The scale is
divided in 10 parts. The value of each
part corresponds to 1/10 of the full scale
FS.
When the SLIDER m/M-DS2 is “UP”
(Fig. 1) the SP2 is MAX set point.
When the SLIDER is “DOWN” the SP2
is min. set point (in that case, with the
slider A/Ⱥ the condition V=0 is selected
as “ALARM” (UP POSITION) or “NO
ALARM” (DOWN POSITION), fig. 5/1
and 5/2).
The minimum value which can be set is
1/10 of the full scale.
TC
Initial timer adjustable by screwdriver on
the front (0,1÷10 sec) excluding set
point triggerings at the start, for covering
an eventual initial spike. It covers both
the sets points.
The timer is activated when the voltage
overcomes the internal set point Vm
(Vm corresponds to 1/10 of the range.
Ex.: VFS=100V, Vm=10V).
T1
Timer delaying the internal relay
associated to the set point SP1 (0,1÷10
sec).
T2
Timer like T1 for the set point SP2
MODE OF OPERATION
When the voltage is applied at the input,
the timer TC bypasses the eventual
spike. After the end of TC, each set
point triggers after the delay time T1 and
T2.
INPUTS
Voltage pins: 19-17.
Input Resistance = 5 kW/V.
OUTPUT RELAY
5A(NO) 3A(NC)-230 Vac resistive load
R1 9-10 NO
9-8 NC Device not supplied
R2 5-6 NO or in alarm
5-4 NC
SUPPLY: (single voltage)
2VA 50-60 Hz - tolerance ±10%
13-12: 24Vac or 48Vac or 115Vac or
230 Vac
CASE
70x75x110 mm for DIN rail.
WORKING TEMPERATURE: 0÷70°C
WEIGHT: Kg 0,300
COLOUR: grey, similar to RAL 35.
For alternating voltages 10V÷500Vac.
Second set point programmable as min
or max set point.
REMARK: it can replace the relay E 424
(only alternating voltage) and V1-01N.
FUNCTION
The device controls an alternating
voltage at the input, by two set points:
one max set point and the second can
be set as min or max set point.
USE
The device controls the alternating
voltage at the input.