Examine the Online Catalog of Industrial Supplies for Euchner
Great Offers at Unbeatable Prices
Extensive Selection
Quick Shipping
Sale of any product from the catalog Euchner
Brand name
Euchner
tpl10.product.param.model
TZ1LE024MVAB
Article
083965
Country
Germany
- Auxiliary release on the front
- Two LED indicators, red and green
- Actuating head fitted left
- 24 V AC/DC -15%, +10%
TZ1 | Closed-circuit current principle, guard locking by spring force. Release by applying voltage to the solenoid. |
SK | For monitoring the door/actuator position |
UK | For monitoring the guard locking (built-in solenoid) |
2131H | Slow-action switching contact 3 NC + 1 NO |
3131H | Slow-action switching contact 2 NC + 2 NO |
Housing material | Anodized die-cast alloy |
Weight | |
Net | 1,2 kg |
Ambient temperature | -25 ... 80 °C |
Degree of protection | IP67 |
Mechanical life | 1 x 106 |
Contact material | Silver alloy, gold flashed |
Switching principle | Slow-action switching contact |
Installation orientation | Any |
Number of door position positively driven contacts | 3 |
Number of door position NO contacts | 1 |
Number of guard lock monitoring positively driven contacts | 2 |
Number of guard lock monitoring NO contacts | 2 |
Connection | |
1 x | M20 x 1.5 |
Approach speed | max.20 m/min |
Actuation frequency | 1200 1/h |
Guard locking principle | Closed-circuit current principle |
Locking force Fmax | 2000 N |
Locking force FZh | 1500 N |
Retention force | 10 N |
Extraction force | 30 N |
Actuating force | 35 N |
Insertion depth | min.52 mm |
Cover lid | Black |
Thermal rated current Ith | 4 A 70°C => 2A'> |
Utilization category according to EN 60947-5-1 | |
AC-15 | 4A 230V 70°C => 2A'> |
DC-13 | 4A 24V 70°C => 2A'> |
Solenoid operating voltage | |
AC/DC | 24 V -15% ... +10% |
Short circuit protection according to IEC 60269-1 | |
(Fuse) | 4A gG 70°C => 2A gG'> |
Rated insulation voltage Ui | 250 V |
Rated impulse withstand voltage Uimp | 2,5 kV |
Switching voltage | |
Min. at 10mA | 12 V |
Switching current | |
Min. at 24V | 1 mA |
Power consumption | 10 W |
Solenoid duty cycle | 100 % |
Connection cross-section | 0,34 ... 1,5 mm? |
LED indicator | Operating voltage corresponds to the solenoid voltage |
Control of the guard locking | |
Category | Depending on external control of guard locking |
Performance Level | Depending on external control of guard locking |
PFHD | Depending on external control of guard locking |
Monitoring of guard locking and the safety guard position | |
B10D | 3 x 106 |
Overtravel | 16 mm |
Overtravel | 4 mm |
Euchner Safety Switch
- Delivery of spare parts and industrial equipment throughout the USA by Fedex transport company.
- Flexible payment system accepting bank transfers, MasterCard, VISA, PayPall, App Pay, Google Pay.
- Directly from stock and on order.