  • Four read heads can be connected
  • 1 safety contact
  • 1 auxiliary contact
  • 1 feedback loop can be connected
Functional The evaluation unit CMS-E-BR is suitable for the direct connection of up to 4 read heads. Category/PL according to EN ISO 13849-1
  • Category 3/PL d with more than one read head connected
  • Category 4/PL e with only one read head connected
Notice:At low approach speeds in the z direction, the time offset when switching the reed contacts must not be more than 150 ms. Dimension drawing Wiring diagram CMS: Magnetically coded safety switches Dimension drawingWiring diagram Technical dataApprovals Mechanical values and environment
Housing material Polycarbonate (PC)
Weight
Net 0,24 kg
Ambient temperature 0 ... 50 °C
Degree of protection Terminals IP20 / housing IP40
Mechanical life 30 x 106
Mounting method Mounting rail 35mm according to DIN EN 60715 TH35
Number of read heads Up to 4 read heads
Connection Connection terminals, plug-in
Safety contacts 13/14
Number of safety contacts 1
Auxiliary contacts 23/24
Number of auxiliary contacts 1
Electrical connection ratings
Operating voltage
AC/DC 24 V -10% ... +10%
Fusing
Protection internal (operating voltage UB) 0,5 A Automatically resetting fuse PTC
Rated insulation voltage Ui
AC 250 V
Degree of contamination (external, according to EN 60947-1) 2
Connection cross-section 0,14 ... 2,5 mm?
LED indicator 1 indicator LED Power (UB) green 1 LED safety output (OUT green/red) 8 LED status indicators (Dx1 / Dx2 /green/ red)
Safety contacts 13/14
Type of output Relay contacts, floating
Current consumption 250 mA
Switching voltage
AC max.250 V
Switching current
at DC 24V 13 ... 3000 mA
Fusing
External contact fuse (safety circuit) acc. to EN IEC 60269-1 3A gG
Utilization category according to EN 60947-4-1
Utilization category according to EN 60947-5-1
AC-15 1A , 250V , 1A 24V
DC-13 3A , 24V
Switching load
Switching load acc. to UL Class 2 Input: 24V AC/DC : Output: 30V AC , 24V DC
Breaking capacity (VA) max.750 VA
Risk time according to EN 60947-5-3 20 ms
Auxiliary contacts 23/24
Type of output Relay contact, floating
Other
In compliance with EN ISO 13849-1: 2015, EN 50178: 1997, EN ISO 14119: 2013, EN 6100-6-3: 2007, EN 60947-5-2: 2007/A1: 2012, EN 60947-5-3: 2013
Reliability values according to EN ISO 13849-1
Monitoring of the safety guard position
Category
With one read head 4
With more than one read head 3
Performance Level
With one read head PL e
With more than one read head PL d
PFHD
With one read head 2.5 x 10-8
With more than one read head 1.0 x 10-7
Number of switching cycles
? 0.1A at 24V DC max.100000 1/Jahr
? 1A at 24V DC max.18500 1/Jahr
? 3A at 24V DC max.9000 1/Jahr
Mission time 20 y
In combination with Read head CMS-R-AXH-03V, CMS-R-AXH-SC and Actuator CMS-M-ACOperating distance
Center offset
At s=3 mm read distance 2,5 mm
Assured switch-off distance Sar max.31 mm
Assured operating distance Sao
With center offset m=0 min.6 mm
In combination with Read head CMS-R-BXI-03V, CMS-R-BXI-05V, CMS-R-BXI-SC, CMS-R-BXI-07P and Actuator CMS-M-BDOperating distance
Center offset
At s=3 mm read distance 2,5 mm
Assured switch-off distance Sar max.12 mm
Assured operating distance Sao
With center offset m=0 min.3 mm
In combination with Read head CMS-R-CXC-03V, CMS-R-CXC-05V, CMS-R-CXC-05P, CMS-R-CXC-SC and Actuator CMS-M-CAOperating distance
Center offset
At s=3 mm read distance 2,5 mm
Assured switch-off distance Sar max.14 mm
Assured operating distance Sao
With center offset m=0 min.6 mm
In combination with Read head CMS-R-EXM-03V, CMS-R-EXM-05V, CMS-R-EXM-SC and Actuator CMS-M-EFOperating distance
Center offset
At s=3 mm read distance 2,5 mm
Assured switch-off distance Sar max.17 mm
Assured operating distance Sao
With center offset m=0 min.6 mm

The 085537 industrial spare part is crafted with precision to ensure your machinery operates at peak efficiency. Engineered for industrial products in demanding environments, it guarantees reduced downtime and increased productivity. 085537 components are built to withstand the toughest industrial conditions, making them essential for keeping your operations in the USA running smoothly.

Euchner offers a wide selection of industrial spare parts for different applications. Whether you’re performing maintenance or replacing worn-out parts, 085537 provides long-lasting, reliable solutions. Order your 085537 spare part today for fast delivery across the USA and keep your equipment performing at its best.

For industrial components and spare parts, trust Euchner to supply top-tier products that enhance the lifespan and efficiency of your machinery.

  • Delivery of spare parts and industrial equipment throughout the USA by Fedex transport company.
  • Flexible payment system accepting bank transfers, MasterCard, VISA, PayPall, App Pay, Google Pay.
  • Directly from stock and on order.