  • Safety switch with integrated evaluation electronics
  • Up to 20 switches in series
  • Short circuit monitoring
  • 2 safety outputs (semiconductor outputs)
  • Door hinge left
  • Category 4/PL e according to EN ISO 13849-1
  • Plug connector M8, 8-pin
  • Multicode
  • Two safety screws M4x14 included
Short circuit monitoring The switch generates its own clock signal on the output cables OA/OB. Pay attention to this aspect when connecting to control systems and relays. Multicode evaluation Every suitable actuator is detected by the switch. Category according to EN 13849-1 Due to two redundantly designed semiconductor outputs (safety outputs) with internal monitoring suitable for:
  • Category 4/PL e according to EN 13849-1
Important: To achieve the stated category in accordance with EN ISO 13849-1, both safety outputs (OA and OB) must be evaluated. LED indicator
STATEStatus LED
DIADiagnostics LED
Additional connections
OUTMonitoring output (semiconductor)
RSTReset input
Approach directions Typical operating distance (Actuator CES-A-BLN... in conjunction with safety switch CES-AR-C.2-... in case of mounting on plastic) For a side approach direction for the actuator and safety switch, a minimum distance of s = 6 mm must be maintained so that the operating distance of the side lobes is not entered. Attention: The operating distance may vary depending on the background material and installation situation. Connector assignment
Plug connector (view of connection side) Pin Designation Function Conductor coloring of connection cable
1 IB Enable input for channel 2 WH
2 UB Power supply, DC 24 V BN
3 OA Safety output, channel 1 GN
4 OB Safety output, channel 2 YE
5 OUT Monitoring output GY
6 IA Enable input for channel 1 PK
7 0V Ground, DC 0 V BU
8 RST Reset input RD
Housing material Plastic, PBT
Weight
Net 0,04 kg
Ambient temperature -25 ... 65 °C
Degree of protection IP67, IP69K
Resilience to vibration In acc. with EN IEC 60947-5-2
Mounting method Surface mounting on metal
Mounting distance
Between 2 switches or 2 actuators min.120 mm
Installation orientation Any
Tightening torque
Fixing screws max.1 Nm
Ready delay 10 s
Switching frequency max.1 Hz
Connection M8 plug connector, 8-pin
Electrical connection ratings
Operating voltage DC
UB 24 V DC 15% ... 15% Regulated, residual ripple < 5 %
Current consumption max.50 mA
Fusing
External (operating voltage) 0,25 ... 8 A
Rated insulation voltage Ui 75 V
Rated impulse withstand voltage Uimp max.1,5 kV
EMC protection requirements In acc. with EN IEC 60947-5-3
Degree of contamination (external, according to EN 60947-1) 3
Switch-on time
Safety outputs max.400 ms
Safety class III
Risk time according to EN 60947-5-3
Delay per device 5 ms
Single device max.260 ms
Safety outputs OA/OB
Test pulses max.1 ms
Test-pulse interval min.140 ms
Type of output Semiconductor outputs, p-switching, short circuit-proof
Switching current
per safety output 1 ... 200 mA
Output voltage
HIGH U(OA) / U(OB) UB-1,5V ... UB V DC
LOW U(OA) / U(OB) 0 ... 1 V DC
Utilization category according to EN 60947-5-2
DC-13 24V 200mA
Rated conditional short-circuit current 100 A
Off-state current Ir max.0,25 mA
Discrepancy time max.10 ms
Monitoring output OUT
Type of output p-switching, short circuit-proof
Switching current max.50 mA
Output voltage 0,8 x UB ... UB V DC
Work area
Repeat accuracy R ? 10
Other
For the approval according to UL the following applies Operation only with UL class 2 power supply, or equivalent measures
Reliability values according to EN ISO 13849-1
Monitoring of the safety guard position
Category 4
Performance Level PL e
PFHD 1.9 x 10-9
Mission time 20
In combination with Actuator CES-A-BLN-R2-100776, CES-A-BLN-U2-103450, CES-A-BLN-L2-104510, CES-A-BLN-U2-112710Operating distance
Switch-on distance 15 mm
Assured switch-off distance Sar
In y direction max.60 mm
In x/z direction max.40 mm
Assured operating distance Sao min.10 mm
Switching hysteresis min.1 mm
In combination with Actuator CES-A-BDN-06-104730Operating distance
Switch-on distance 19 mm
Assured switch-off distance Sar
In y direction max.60 mm
In x/z direction max.40 mm
Assured operating distance Sao min.14 mm
Switching hysteresis min.1 mm

The 105752 industrial spare part is crafted with precision to ensure your machinery operates at peak efficiency. Engineered for industrial products in demanding environments, it guarantees reduced downtime and increased productivity. 105752 components are built to withstand the toughest industrial conditions, making them essential for keeping your operations in the USA running smoothly.

Euchner offers a wide selection of industrial spare parts for different applications. Whether you’re performing maintenance or replacing worn-out parts, 105752 provides long-lasting, reliable solutions. Order your 105752 spare part today for fast delivery across the USA and keep your equipment performing at its best.

For industrial components and spare parts, trust Euchner to supply top-tier products that enhance the lifespan and efficiency of your machinery.

  • Delivery of spare parts and industrial equipment throughout the USA by Fedex transport company.
  • Flexible payment system accepting bank transfers, MasterCard, VISA, PayPall, App Pay, Google Pay.
  • Directly from stock and on order.