Examine the Online Catalog of Industrial Supplies for Euchner
- Safety switch with guard locking and integrated evaluation electronics
- Locking force up to 6500 N
- Up to 20 switches in series
- Short circuit monitoring
- 2 safety outputs (semiconductor outputs)
- Up to category 4/PL e according to EN ISO 13849-1
- With 2 plug connectors M12
- Multicode
- Door monitoring output
- Indication of the door position by LED
- Wire front release (bowden), 3m, automatic return
- Approach direction A (default setting on delivery)
- DC 24 V +10% -15%
CET3 | Closed-circuit current principle, guard locking by spring force. Release by applying voltage to the guard locking solenoid. The door position is also monitored. The door monitoring output OUT D is set to HIGH as soon as the actuator is above the extended plunger (state: door closed, guard locking not active). The output OUT D remains set also with guard locking active. |
LED State | Status LED |
LED DIA | Diagnostic LED |
LED 1 rd | freely configurable |
LED 2 gn | illuminates when door is closed |
OUT | Monitoring output (semiconductor) |
OUT D | Door monitoring output |
RST | Reset input |
- Category 4/PL e according to EN ISO 13849-1
Housing material | |
Safety switch housing | Die-cast aluminum |
Slide | Stainless steel |
Weight | |
Net | 1 kg |
Ambient temperature | |
At UB = 24V DC | -20 ... 55 °C |
Degree of protection | IP67 |
Resilience to vibration | In acc. with EN IEC 60947-5-2 |
Mechanical life | 1 x 106 |
Installation orientation | Any |
Degree of freedom | |
X | ±5 mm |
Y | ±5 mm |
Z | ±4 mm |
Ready delay | 10 s |
Switching frequency | max.0,5 Hz |
Connection | 2 plug connectors M12, 5 and 8-pin |
Approach speed | 20 m/min |
Guard locking principle | Closed-circuit current principle |
Locking force Fmax | 6500 N |
Locking force FZh | 5000 N |
Operating voltage DC | |
LED | 24 V DC -15% ... 10% |
UB | 24 V DC -15% ... 15% Reverse polarity protected, regulated, residual ripple < 5%, PELV |
Current consumption | |
IB | 80 mA |
ICM | 480 mA |
Utilization category according to EN 60947-5-2 | |
DC-13 | 24V 200mA |
Solenoid operating voltage DC | |
UCM | 24 V DC -15% ... +10% Reverse polarity protected, regulated, residual ripple < 5%, PELV |
Fusing | |
External (solenoid operating voltage UCM) | 0,5 ... 8 A |
External (operating voltage UB) | 0,25 ... 8 A |
Power consumption | |
Solenoid | max.12 W |
EMC protection requirements | In acc. with EN IEC 60947-5-3 |
Solenoid duty cycle | 100 % |
Degree of contamination (external, according to EN 60947-1) | 3 |
Connecting cable | 30V DC, 2A |
Safety class | |
EN IEC 61140 | III |
Switching load | |
According to UL | 24V DC, class 2 |
Safety outputs OA/OB | |
Type of output | 2 semiconductor outputs, p-switching, short circuit-proof |
Switching current | |
Per safety output OA / OB | 1 ... 200 mA |
Output voltage | |
High U(OA) / U(OB) | UB-1,5V ... UB V DC |
Low U(OA) / U(OB) | 0 ... 1 V DC |
Off-state current Ir | max.0,25 mA |
Risk time according to EN 60947-5-3 | |
Single device | max.400 ms |
Delay per device | 5 ms |
Switch-on time | 400 ms |
Discrepancy time | |
Both safety outputs | max.10 ms |
Monitoring output OUT | |
Type of output | p-switching, short circuit-proof |
Switching current | |
OUT | 1 ... 50 mA |
Output voltage | |
OUT | 0,8xUB ... UB V DC |
Switching delay from state change | max.400 ms |
Monitoring output OUT D | |
Type of output | p-switching, short circuit-proof |
Switching current | |
OUT D | 1 ... 50 mA |
Output voltage | |
OUT D | 0,8xUB ... UB V DC |
Switching delay from state change | max.700 ms |
Repeat accuracy R | 10 % |
C number | |
C2290 | With wire front release (bowden) mounted |
For the approval according to UL the following applies | Operation only with UL class 2 power supply, or equivalent measures see operating instructions |
Control of the guard locking | |
Category | Depending on external control of guard locking |
Performance Level | Depending on external control of guard locking |
PFHD | Depending on external control of guard locking |
Monitoring of guard locking and the safety guard position | |
Category | |
Head downward or horizontal | 4 |
Head upward | 3 |
Performance Level | PL e |
PFHD | |
Head downward or horizontal | 3.1 x 10-9 |
Head upward | 4.29 x 10-8 |
Mission time | 20 y |
The 110114 industrial spare part is crafted with precision to ensure your machinery operates at peak efficiency. Engineered for industrial products in demanding environments, it guarantees reduced downtime and increased productivity. 110114 components are built to withstand the toughest industrial conditions, making them essential for keeping your operations in the USA running smoothly.
Euchner offers a wide selection of industrial spare parts for different applications. Whether you’re performing maintenance or replacing worn-out parts, 110114 provides long-lasting, reliable solutions. Order your 110114 spare part today for fast delivery across the USA and keep your equipment performing at its best.
For industrial components and spare parts, trust Euchner to supply top-tier products that enhance the lifespan and efficiency of your machinery.
- Delivery of spare parts and industrial equipment throughout the USA by Fedex transport company.
- Flexible payment system accepting bank transfers, MasterCard, VISA, PayPall, App Pay, Google Pay.
- Directly from stock and on order.