- Guard locking with guard lock monitoring
- With plug connector RC18
- Mounted on mounting plates
- With escape release
- Unicode
Guard locking type
MGB-L1... | The locking arm is held in the locked position by spring force and is unlocked by solenoid force (closed-circuit current principle, mechanically locked). |
Door stopA mechanical door stop is permanently integrated into the evaluation module of the MGB. A marking on the stop makes adjustment easier. LED indicatorThe LED indicator indicates all important system and status information. Monitoring outputs
OD | ON when the door is closed |
OT | Bolt tongue inserted into the evaluation module |
OI | Diagnostics, there is a fault |
NoticeThe interlocking module, handle module and the escape release are each pre-assembled on a mounting plate. Escape release The escape release enables people accidentally shut in to open the guard locked door from the danger zone. Dimension drawing Dimension drawing Plug connector RC18 MGB: The MGB-System in use MGB: MGB Impact test MGB: Mounting left door, with escape release Mounting left door, without escape release Mounting right door, without escape release MGB: Changing series wiring (AR) to single wiring (AP) MGB: Deactivating guard lock monitor MGB: Activating guard lock monitor MGB: Activating release monitoring MGB: Change color-lens push button Dimension drawingDimension drawingPlug connector RC18 Technical data Locking module MGB-L1-APA-AA1A2-S1-R-112597 (Order no. 112597) Mechanical values and environment
Housing material | Reinforced plastic, die-cast zinc nickel-plated, stainless steel |
Weight | |
Net | 1,35 kg |
Ambient temperature | |
At UB = 24V DC | -20 ... 55 °C |
Degree of protection | IP65 |
Mechanical life | 1 x 106 |
In case of use as door stop, and 1 Joule impact energy | 0,1 x 106 |
Installation orientation | Door hinge DIN right |
Switching frequency | 0,25 Hz |
Connection | Plug connector RC18 |
Guard locking principle | Closed-circuit current principle |
Locking force FZh | 2000 N |
Electrical connection ratings
Utilization category according to EN 60947-5-2 | |
DC-13 | 24V 200mA |
Rated insulation voltage Ui | 30 V |
Rated impulse withstand voltage Uimp | 1,5 kV |
Degree of contamination (external, according to EN 60947-1) | 3 |
Safety class | III |
Discrepancy time | |
Between FO1A and FO1B | max.10 ms |
Risk time according to EN 60947-5-3 | max.350 ms |
Transponder coding | Unicode |
| Monitoring outputs OD, OT, OL, OI |
Type of output | Semiconductor outputs, p-switching, short circuit-proof |
Output voltage | UA-2V ... UA V DC |
Output current | max.50 mA |
| Solenoid control input IMP1, IMP2, IMM |
Test pulses | max.5 ms |
Test-pulse interval | min.100 ms |
| Power supply UB |
Operating voltage DC | |
UB | 24 V DC -15% ... 10% |
Current consumption | |
IUB | max.80 mA |
| Power supply UA |
Operating voltage DC | |
UA | 24 V DC -15% ... 10% |
Current consumption | |
IUA | max.375 mA |
| Safety outputs FO1A, FO1B |
Test pulses | max.0,3 ms |
Test-pulse interval | min.100 ms |
Type of output | Semiconductor outputs, p-switching, short circuit-proof |
Output voltage | |
UFO1A /UFO1B HIGH | UB-2V ... UB V DC |
UFO1A /UFO1B LOW | 0 ... 1 V DC |
Output current | |
Per safety output FO1A / FO1B | 1 ... 200 mA |
Other
Additional feature | Mounting plate |
Product version number | V3.0.3 |
Reliability values according to EN ISO 13849-1
| Monitoring of guard locking and the safety guard position |
Category | 4 |
Performance Level | PL e |
PFHD | 3.7 x 10-9 |
| Control of the guard locking |
Category | 4 |
Performance Level | PL e |
PFHD | 2.8 x 10-9 |
Mission time | 20 y |
Handle module MGB-H-AA1A6-R-111838 (Order no. 111838) Mechanical values and environment
Housing material | Reinforced plastic, die-cast zinc nickel-plated, stainless steel |
Weight | |
Net | 1,00 kg |
Ambient temperature | -20 ... 55 °C |
Degree of protection | IP65 |
Installation orientation | Door hinge DIN right |
Other
Additional feature | With mounting plate and automatic lockout mechanism |
Product version number | V3.0.0 |
Escape release MGB-E-A2-106051 (Order no. 106051) Mechanical values and environment
Housing material | Die-cast zinc/stainless steel powder-coated |
Weight | |
Net | 1,05 kg |
Ambient temperature | -20 ... 55 °C |
Mechanical life | 1 x 106 |
Installation orientation | Any |
Other
Additional feature | With mounting plate |
Product version number | V2.0.0 |
Components 112597 Locking module MGB-L1-APA-AA1A2-S1-R-112597
- Guard locking with guard lock monitoring
- With plug connector RC18
- Mounted on mounting plate
- Unicode
111838 Handle module MGB-H-AA1A6-R-111838
- Intelligent bolt tongue
- Fold-out lockout mechanism
- Second automatically extending lockout mechanism
- Door handle
- Mounting plate
106051 Escape release MGB-E-A2-106051
- Escape release out of the danger area
- Mounted on mounting plate
- With red handle
- 118 mm long