STATE | Status LED |
DIA | Diagnostics LED |
Plug connector (view of connection side) | Pin | Designation | Function | Conductor coloring of connection cable |
---|---|---|---|---|
1 | UB | Power supply, DC 24 V | BN | |
2 | FO1A | Safety output, channel 1 | WH | |
3 | 0V | Ground, DC 0 V | BU | |
4 | FO1B | Safety output, channel 2 | BK | |
5 | - | n.c. | GY |
Plug connector (view of connection side) | Pin | Designation | Function | Conductor coloring of connection cable |
---|---|---|---|---|
1 | H1 | Data line | BN | |
3 | H2 | Data line | WH | |
4 | SH | Shield | - |
Housing material | Plastic, PBT |
Weight | |
Net | 0,096 kg |
Ambient temperature | |
Cable static | -20 ... 65 °C |
Cable dynamic | -5 ... 65 °C |
Degree of protection | IP67 |
Resilience to vibration | In acc. with EN IEC 60947-5-2 |
Installation orientation | Any |
Tightening torque | max.1 Nm |
Ready delay | 1 s |
Switching frequency | max.1 Hz |
Connection | Connection cable PUR with plug connector M12 5-pin, pin 5 not used |
Operating voltage DC | |
UB(PELV, see operating instructions) (reverse polarity protected, regulated, residual ripple < 5%) | 24 V DC 15% ... 15% |
Current consumption | max.45 mA |
Fusing | |
External (operating voltage) | 0,25 ... 8 A |
Rated insulation voltage Ui | 75 V |
Rated impulse withstand voltage Uimp | max.1,5 kV |
EMC protection requirements | In acc. with EN IEC 60947-5-3 |
Degree of contamination (external, according to EN 60947-1) | 3 |
Switch-on time | |
Safety outputs | max.400 ms |
Safety class | III |
Risk time according to EN 60947-5-3 | max.260 ms |
Safety outputs FO1A / FO1B | |
Type of output | Semiconductor outputs, p-switching, short circuit-proof |
Switching current | |
per safety output | 1 ... 150 mA |
Output voltage | |
HIGH U(FO1A) / U(FO1B) | UB-1,5V ... UB V DC |
LOW U(FO1A) / U(FO1B) | 0 ... 1 V DC |
Utilization category according to EN 60947-5-2 | |
DC-13 | DC-13 24V 150mA |
Off-state current Ir | max.0,25 mA |
Discrepancy time | max.10 ms |
Repeat accuracy R | ? 10 |
For the approval according to UL the following applies | Operation only with UL class 2 power supply, or equivalent measures |
Monitoring of the safety guard position | |
Category | 4 |
Performance Level | PL e |
PFHD | 4.5 x 10-9 |
Mission time | 20 |
Switch-on distance | 5 mm |
Assured switch-off distance Sar | max.10 mm |
Assured operating distance Sao | min.3,4 mm |
Switching hysteresis | min.0,05 mm |
The 115534 industrial spare part is crafted with precision to ensure your machinery operates at peak efficiency. Engineered for industrial products in demanding environments, it guarantees reduced downtime and increased productivity. 115534 components are built to withstand the toughest industrial conditions, making them essential for keeping your operations in the USA running smoothly.
Euchner offers a wide selection of industrial spare parts for different applications. Whether you’re performing maintenance or replacing worn-out parts, 115534 provides long-lasting, reliable solutions. Order your 115534 spare part today for fast delivery across the USA and keep your equipment performing at its best.
For industrial components and spare parts, trust Euchner to supply top-tier products that enhance the lifespan and efficiency of your machinery.
- Delivery of spare parts and industrial equipment throughout the USA by Fedex transport company.
- Flexible payment system accepting bank transfers, MasterCard, VISA, PayPall, App Pay, Google Pay.
- Directly from stock and on order.