Examine the Online Catalog of Industrial Supplies for Euchner
- Safety switch with guard locking and integrated evaluation electronics
- Short circuit monitoring
- Two safety outputs (semiconductor outputs)
- Bistable guard locking
- Up to category 4/PL e according to EN ISO 13849-1
- With plug connector M12
- Unicode
- Door monitoring output
- Approach directions A, B and C (delivery state)
CTP?LBI | Guard locking operated by means of input signal. |
- persons from unintentionally locking themselves inside if the safety door is open in case of a power failure or if the machine is switched off.
- the deactivation of the activated guard locking in case of a power failure.
Plug connector (view of connection side) | Pin | Designation | Function | Conductor coloring of connecting cable |
---|---|---|---|---|
1 | IMP | Operating voltage of guard locking solenoid 24 V DC | WH | |
2 | UB | Operating voltage of AP electronics 24 V DC | BN | |
3 | FO1A | Safety output, channel 1 | GN | |
4 | FO1B | Safety output, channel 2 | YE | |
5 | OI | Diagnostic output | GY | |
6 | OD | Door monitoring output | PK | |
7 | OL | Guard locking monitoring output | BU | |
8 | 0 V UB | Control input of guard locking solenoid, 0 V | RD |
Housing material | |
Switch head cover | Die-cast zinc |
Safety switch housing | Fiber glass reinforced thermoplastic |
Weight | |
Net | 0,42 kg |
Ambient temperature | |
At UB = 24V DC | -20 ... +55 °C |
Degree of protection | IP67 / IP69 / IP69K |
Resilience to vibration | In acc. with EN IEC 60947-5-3 |
Mechanical life | 1 x 106 |
Installation orientation | Any |
Ready delay | max.1 s |
Switching frequency | max.0,5 Hz |
Connection | 1 plug connector M12, 8-pin |
Approach speed | 20 m/min |
Guard locking principle | BiState |
Locking force Fmax | 3900 N |
Locking force FZh | 3000 N |
Retention force | 5 N |
Extraction force | 10 N |
Actuating force | 8 N |
Overtravel | 5 mm |
Operating voltage DC | |
UUB | 24 V DC -15% ... 15% Reverse polarity protected, regulated, residual ripple < 5%, PELV |
Current consumption | |
IUB (IMP=HIGH) | 440 mA |
IUB (IMP=LOW) | 40 mA |
IIMP (IMP=HIGH) | 20 mA |
Utilization category according to EN 60947-5-2 | |
DC-13 | 24V 150mA |
Fusing | |
External (operating voltage UB) | 0,5 ... 8 A |
Rated insulation voltage Ui | max.50 V |
Rated impulse withstand voltage Uimp | max.0,5 kV |
Power consumption | 1,7 W |
EMC protection requirements | In acc. with EN IEC 60947-5-3 |
Solenoid duty cycle | 100 % |
Degree of contamination (external, according to EN 60947-1) | 3 |
Control voltage | |
UIMP (HIGH) | 15 ... 24 V |
UIMP (LOW) | 0 ... 5 V |
Safety class | |
EN IEC 61140 | III |
Switching load | |
According to UL | 24V DC, class 2 |
Safety outputs FO1A / FO1B | |
Test pulses | max.0,3 ms |
Test-pulse interval | min.100 ms |
Type of output | 2 semiconductor outputs, p-switching, short circuit-proof |
Switching current | |
Per safety output FO1A / FO1B | 1 ... 150 mA |
Output voltage | |
Low U(FO1A) / U(FO1B) | 0 ... 1 V DC |
High U(FO1A) / U(FO1B) | UB-1,5 ... UB V DC |
Off-state current Ir | max.0,25 mA |
Switch-on time | max.400 ms |
Discrepancy time | |
Both safety outputs | max.10 ms In acc. with EN IEC 60947-5-3 |
Monitoring output OL | |
Type of output | p-switching, short circuit-proof |
Switching current | 1 ... 50 mA |
Output voltage | 0,8xUB ... UB V DC |
Monitoring output OD | |
Type of output | p-switching, short circuit-proof |
Switching current | 1 ... 50 mA |
Output voltage | 0,8xUB ... UB V DC |
Monitoring output OI | |
Type of output | p-switching, short circuit-proof |
Switching current | 1 ... 50 mA |
Output voltage | 0,8xUB ... UB V DC |
Repeat accuracy R | 10 % |
For the approval according to UL the following applies | Operation only with UL class 2 power supply, or equivalent measures see operating instructions |
Guard lock monitoring | |
Mission time | 20 y |
Category | 4 |
Performance Level | PL e |
PFHD | 4.1 x 10 -9 |
Guard locking control | |
Mission time | 20 y |
Category | B |
Performance Level | PL b |
PFHD | 2.1 x 10 -9 |
The 127798 industrial spare part is crafted with precision to ensure your machinery operates at peak efficiency. Engineered for industrial products in demanding environments, it guarantees reduced downtime and increased productivity. 127798 components are built to withstand the toughest industrial conditions, making them essential for keeping your operations in the USA running smoothly.
Euchner offers a wide selection of industrial spare parts for different applications. Whether you’re performing maintenance or replacing worn-out parts, 127798 provides long-lasting, reliable solutions. Order your 127798 spare part today for fast delivery across the USA and keep your equipment performing at its best.
For industrial components and spare parts, trust Euchner to supply top-tier products that enhance the lifespan and efficiency of your machinery.
- Delivery of spare parts and industrial equipment throughout the USA by Fedex transport company.
- Flexible payment system accepting bank transfers, MasterCard, VISA, PayPall, App Pay, Google Pay.
- Directly from stock and on order.