Supply of spare parts for industrial enterprises in the USA
Home Brands Euchner 136841 CTP-L2-AP-U-HA-AE-SA-136841

Euchner CTP-L2-AP-U-HA-AE-SA-136841 136841

 CTP-L2-AP-U-HA-AE-SA-136841 Euchner 136841

Examine the Online Catalog of Industrial Supplies for Euchner


Great Offers at Unbeatable Prices
Great Offers at Unbeatable Prices
Discover incredible savings on industrial spare parts and components
Extensive Selection
Extensive Selection
Explore a wide variety of industrial spare parts to find the ideal fit for your needs
Quick Shipping
Quick Shipping
Get your industrial parts delivered promptly—right to your door!
Sale of any product from the catalog Euchner
Brand name
Euchner
tpl10.product.param.model
CTP-L2-AP-U-HA-AE-SA-136841
Article
136841
Country
Germany
  • Safety switch with guard locking and integrated evaluation electronics
  • Short circuit monitoring
  • Two safety outputs (semiconductor outputs)
  • Up to category 4/PL e according to EN ISO 13849-1
  • With plug connector M12
  • Unicode
  • Door monitoring output
  • With escape release
  • Approach directions A, B and C (delivery state)
Approach direction Horizontal Can be adjusted in 90° steps Each actuator is unique. The switch detects only taught-in actuators. Additional actuators can be taught in. Only the last actuator taught in is detected. Guard locking type
CTP?L2Guard locking actuated by power-ON applied and spring released (open-circuit current principle).
Escape release This is used for manual release of guard locking from the danger zone without tools. Connector assignment
Plug connector (view of connection side) Pin Designation Function Conductor coloring of connecting cable
1 IMP Operating voltage of guard locking solenoid 24 V DC WH
2 UB Operating voltage of AP electronics 24 V DC BN
3 FO1A Safety output, channel 1 GN
4 FO1B Safety output, channel 2 YE
5 OI Diagnostic output GY
6 OD Door monitoring output PK
7 0 V UB Operating voltage of AP electronics 0 V BU
8 IMM Operating voltage of guard locking solenoid 0 V RD
Housing material
Switch head cover Die-cast zinc
Safety switch housing Fiber glass reinforced thermoplastic
Weight
Net 0,42 kg
Ambient temperature
At UB = 24V DC -20 ... +55 °C
Degree of protection IP67 / IP69 / IP69K
Resilience to vibration In acc. with EN IEC 60947-5-3
Mechanical life 1 x 106
Installation orientation Any
Ready delay max.1 s
Switching frequency max.0,5 Hz
Connection 1 plug connector M12, 8-pin
Approach speed 20 m/min
Guard locking principle Open-circuit current principle
Locking force Fmax 3900 N
Locking force FZh 3000 N
Retention force 20 N
Extraction force 20 N
Actuating force 10 N
Overtravel 5 mm
Electrical connection ratings
Test-pulse interval min.100 ms
Test pulses max.0,3 ms
Operating voltage DC
UUB 24 V DC -15% ... 15% Reverse polarity protected, regulated, residual ripple < 5%, PELV
Current consumption
IUB 40 mA
IIMP 400 mA
Utilization category according to EN 60947-5-2
DC-13 24V 150mA
Solenoid operating voltage DC
UIMP 24 V DC -15% ... +10% Reverse polarity protected, regulated, residual ripple < 5%, PELV
Fusing
External (operating voltage UB) 0,25 ... 2 A
External (solenoid operating voltage IMP) 0,5 ... 8 A
Rated insulation voltage Ui max.50 V
Rated impulse withstand voltage Uimp max.0,5 kV
Power consumption 6 W
EMC protection requirements In acc. with EN IEC 60947-5-3
Solenoid duty cycle 100 %
Degree of contamination (external, according to EN 60947-1) 3
Safety class
EN IEC 61140 III
Switching load
According to UL 24V DC, class 2
Safety outputs FO1A / FO1B
Type of output 2 semiconductor outputs, p-switching, short circuit-proof
Switching current
Per safety output FO1A / FO1B 1 ... 150 mA
Output voltage
High U(FO1A) / U(FO1B) UB-1,5 ... UB V DC
Low U(FO1A) / U(FO1B) 0 ... 1 V DC
Off-state current Ir max.0,25 mA
Switch-on time max.400 ms
Discrepancy time
Both safety outputs max.10 ms In acc. with EN IEC 60947-5-3
Monitoring output OD
Type of output p-switching, short circuit-proof
Switching current 1 ... 50 mA
Output voltage 0,8xUB ... UB V DC
Monitoring output OI
Type of output p-switching, short circuit-proof
Switching current 1 ... 50 mA
Output voltage 0,8xUB ... UB V DC
Work area
Repeat accuracy R 10 %
Other
Additional feature Escape release actuated by pushing
For the approval according to UL the following applies Operation only with UL class 2 power supply, or equivalent measures see operating instructions
Reliability values according to EN ISO 13849-1
Performance Level PL e
Category 4
PFHD 4.1 x 10 -9
Mission time 20 y

The 136841 industrial spare part is crafted with precision to ensure your machinery operates at peak efficiency. Engineered for industrial products in demanding environments, it guarantees reduced downtime and increased productivity. 136841 components are built to withstand the toughest industrial conditions, making them essential for keeping your operations in the USA running smoothly.

Euchner offers a wide selection of industrial spare parts for different applications. Whether you’re performing maintenance or replacing worn-out parts, 136841 provides long-lasting, reliable solutions. Order your 136841 spare part today for fast delivery across the USA and keep your equipment performing at its best.

For industrial components and spare parts, trust Euchner to supply top-tier products that enhance the lifespan and efficiency of your machinery.

  • Delivery of spare parts and industrial equipment throughout the USA by Fedex transport company.
  • Flexible payment system accepting bank transfers, MasterCard, VISA, PayPall, App Pay, Google Pay.
  • Directly from stock and on order.