Supply of spare parts for industrial enterprises in the USA
Home Brands Euchner 158631 CES-I-AP-M-C14-U20-158631

Euchner CES-I-AP-M-C14-U20-158631 158631

 CES-I-AP-M-C14-U20-158631 Euchner 158631

Examine the Online Catalog of Industrial Supplies for Euchner


Great Offers at Unbeatable Prices
Great Offers at Unbeatable Prices
Discover incredible savings on industrial spare parts and components
Extensive Selection
Extensive Selection
Explore a wide variety of industrial spare parts to find the ideal fit for your needs
Quick Shipping
Quick Shipping
Get your industrial parts delivered promptly—right to your door!
Sale of any product from the catalog Euchner
Brand name
Euchner
tpl10.product.param.model
CES-I-AP-M-C14-U20-158631
Article
158631
Country
Germany
  • Safety switch with integrated evaluation electronics
  • Safety switch CES-C04 encapsulated in epoxy resin
  • Tested for material resistance in accordance with Ecolab specifications
  • Two safety outputs (semiconductor outputs)
  • Category 4/PL e according to EN ISO 13849-1
  • Three active faces
  • Connecting cable PUR, 20 m, with cable end sleeves
  • Multicode
  • Monitoring output OD
Installation position Permissible installation position Attention:The operating distance may vary depending on the background material and installation situation. (Only in combination with actuator CES-A-BBN) Typical operating distance For a side approach direction for the actuator and safety switch, a minimum distance of s = 10 mm must be maintained so that the operating distance of the side lobes is not entered. Multicode evaluation Every suitable actuator is detected by the switch. Category according to EN 13849-1 Due to two redundantly designed semiconductor outputs (safety outputs) with internal monitoring suitable for:
  • Category 4/PL e according to EN 13849-1
Important: To achieve the stated category according to EN ISO 13849-1, both safety outputs (FO1A and FO1B) must be evaluated. LED indicator
STATEStatus LED
DIADiagnostic LED
Terminal assignment
Designation Function Conductor coloring of connecting cable
UB Power supply, DC 24 V BN
FO1A Safety output, channel 1 WH
0V Ground, DC 0 V BU
FO1B Safety output, channel 2 BK
OD Monitoring output GY
Housing material Two-component epoxy resin
Weight
Net 0,7 kg
Ambient temperature
At UB = DC 24 V 0 ... +50 °C
Cable static -40 ... 80 °C
Cable dynamic -25 ... 80 °C
Degree of protection IP65 / IP67 / IP69 / IP69K
Resilience to vibration In acc. with EN IEC 60947-5-2
Mounting method Surface mounting on metal
Mounting distance
Between 2 switches or 2 actuators min.150 mm
Installation orientation Any
Tightening torque
Fixing screws 2 Nm
Ready delay 10 s
Switching frequency max.1 Hz
Connection connection cable PUR, length 20m
Bending radius
static 5 x cable diameter
Dynamic 10 x cable diameter
Electrical connection ratings
Operating voltage DC
UB 24 V DC 15% ... 15% Regulated, residual ripple < 5%, PELV
Current consumption max.35 mA
Fusing
External (operating voltage) 0,25 ... 8 A
Rated insulation voltage Ui 300 V
Rated impulse withstand voltage Uimp max.1,5 kV
EMC protection requirements In acc. with EN IEC 60947-5-3
Degree of contamination (external, according to EN 60947-1) 3
Switch-on time
Safety outputs max.400 ms
Safety class III
Risk time according to EN 60947-5-3
Delay per device max.260 ms
Monitoring output OD
Type of output Monitoring, semiconductor output, p-switching, short circuit-proof
Switching current max.50 mA
Output voltage 0,8 x UB ... UB V DC
Safety outputs FO1A / FO1B
Test pulses max.1,0 ms
Test-pulse interval min.140 ms
Type of output 2 semiconductor outputs, p-switching, short circuit-proof
Switching current
per safety output 1 ... 200 mA
Output voltage
HIGH U (FO1A1) / U (FO1B) UB-1,5V ... UB V DC
LOW U (FO1A1) / U (FO1B) 0 ... 1 V DC
Utilization category according to EN 60947-5-2
DC-13 24 V 150 mA
Rated conditional short-circuit current 100 A
Off-state current Ir max.0,25 mA
Discrepancy time max.10 ms
Work area
Repeat accuracy R ? 10
Reliability values according to EN ISO 13849-1
Monitoring of the safety guard position
Category 4
Performance Level PL e
PFHD 4.1 x 10-9
Mission time 20
In combination with Actuator CES-A-BBN-C14-160441Operating distance
Switch-on distance
Installation position A / in z direction max.24 mm ALU
max.22 mm PVC
Installation position D / in z direction max.23 mm ALU
max.18 mm PVC
Assured switch-off distance Sar
Installation position D / in x/z direction max.58 mm
Installation position A / in y direction max.72 mm
Installation position A / in x/z direction max.64 mm
Installation position D / in y direction max.68 mm
Assured operating distance Sao
Installation position A / in z direction max.11 mm PVC
max.10 mm ALU
Installation position D / in z direction max.6 mm ALU
max.5 mm PVC

The 158631 industrial spare part is crafted with precision to ensure your machinery operates at peak efficiency. Engineered for industrial products in demanding environments, it guarantees reduced downtime and increased productivity. 158631 components are built to withstand the toughest industrial conditions, making them essential for keeping your operations in the USA running smoothly.

Euchner offers a wide selection of industrial spare parts for different applications. Whether you’re performing maintenance or replacing worn-out parts, 158631 provides long-lasting, reliable solutions. Order your 158631 spare part today for fast delivery across the USA and keep your equipment performing at its best.

For industrial components and spare parts, trust Euchner to supply top-tier products that enhance the lifespan and efficiency of your machinery.

  • Delivery of spare parts and industrial equipment throughout the USA by Fedex transport company.
  • Flexible payment system accepting bank transfers, MasterCard, VISA, PayPall, App Pay, Google Pay.
  • Directly from stock and on order.