- Guard locking with guard lock monitoring
- Can be connected in series with other AR devices (e.g. CES-AR and CET-AR)
- Emergency stop according to ISO 13850
- 2 pushbuttons (illuminated)
- With lens set, 6 pcs.
- With cable entry
- With escape release
- Unicode
Guard locking type
MGB-L2... | The locking arm is held in the locked position by solenoid force and is unlocked by spring force when the solenoid is switched off (open-circuit current principle, electrically locked). |
Door stopA mechanical door stop is permanently integrated into the evaluation module of the MGB. A marking on the stop makes adjustment easier. LED indicatorThe LED indicator indicates all important system and status information. Monitoring outputs
OD | ON when the door is closed |
OT | Bolt tongue inserted into the evaluation module |
OL | Guard locking solenoid in locked position |
OI | Diagnostics, there is a fault |
Emergency stop device
S1 | Two positively driven contacts and one NO contact (e.g. monitoring contact), emergency stop with turn-to-reset, not illuminated |
Pushbutton
S2 | One NO contact, illuminated |
S3 | One NO contact, illuminated |
Lens setThe color of the pushbutton can be selected using the lens set included (five colors). Item no.: 120344 (see Accessories) Escape releaseThe escape release enables people accidentally shut in to open the guard locked door from the danger zone. Dimension drawing Cable entry MGB: The MGB-System in use MGB: MGB Impact test MGB: Mounting left door, with escape release Mounting left door, without escape release Mounting right door, without escape release MGB: Changing single wiring (AP) to series wiring (AR) MGB: Deactivating guard lock monitor MGB: Activating guard lock monitor MGB: Activating release monitoring MGB: Change color-lens push button Dimension drawingCable entry Technical data Locking module MGB-L2-ARA-AM3A1-M-L-121244 (Order no. 121244) Mechanical values and environment
Housing material | Reinforced plastic, die-cast zinc nickel-plated, stainless steel |
Weight | |
Net | 0,75 kg |
Ambient temperature | |
At UB = 24V DC | -20 ... 55 °C |
Degree of protection | IP65 |
Mechanical life | 1 x 106 |
In case of use as door stop, and 1 Joule impact energy | 0,1 x 106 |
Installation orientation | Door hinge DIN left |
Switching frequency | 0,25 Hz |
Connection | Cable entries M20x1.5 |
Guard locking principle | Open-circuit current principle |
Locking force FZh | 2000 N |
Electrical connection ratings
Utilization category according to EN 60947-5-2 | |
DC-13 | 24V 200mA |
Rated insulation voltage Ui | 30 V |
Rated impulse withstand voltage Uimp | 1,5 kV |
Degree of contamination (external, according to EN 60947-1) | 3 |
Connection cross-section | |
(Rigid/flexible) | 0,13 ... 1,5 mm? (AWG 24 ... AWG 16) |
(Rigid/flexible) with cable end sleeve according to DIN 46 228/1 | 0,25 ... 1,5 mm? |
(Rigid/flexible) with cable end sleeve with collar according to DIN 46 228/1 | 0,25 ... 0,75 mm? |
Safety class | III |
Discrepancy time | |
Between FO1A and FO1B | max.10 ms |
Risk time according to EN 60947-5-3 | max.350 ms |
Transponder coding | Unicode |
| Power supply UB |
Operating voltage DC | |
UB | 24 V DC -15% ... 10% |
Current consumption | |
IUB | max.80 mA |
| Power supply UA |
Operating voltage DC | |
UA | 24 V DC -15% ... 10% |
Current consumption | |
IUA | max.375 mA |
| Safety outputs FO1A, FO1B |
Test pulses | max.1 ms |
Test-pulse interval | min.100 ms |
Type of output | Semiconductor outputs, p-switching, short circuit-proof |
Output voltage | |
UFO1A /UFO1B HIGH | UB-2V ... UB V DC |
UFO1A /UFO1B LOW | 0 ... 1 V DC |
Output current | |
Per safety output FO1A / FO1B | 1 ... 200 mA |
| Monitoring outputs OD, OT, OL, OI |
Type of output | Semiconductor outputs, p-switching, short circuit-proof |
Output voltage | UA-2V ... UA V DC |
Output current | max.50 mA |
| Controls and indicators |
Switching voltage | UA V |
Switching current | 1 ... 10 mA |
Breaking capacity | max.0,25 W |
Power supply LED | 24 V DC |
| Emergency stop |
Switching voltage | 5 ... 24 V |
Switching current | 1 ... 100 mA |
Breaking capacity | max.0,25 W |
Power supply LED | 24 V DC |
| Solenoid control input IMP1, IMP2, IMM |
Test pulses | max.5 ms |
Test-pulse interval | min.100 ms |
Other
Additional feature | Incl. cover set ID. No. 120344 |
Product version number | V3.0.3 |
Reliability values according to EN ISO 13849-1
| Monitoring of guard locking and the safety guard position |
Category | 4 |
Performance Level | PL e |
PFHD | 3.7 x 10-9 |
| Emergency stop |
B10D | |
Emergency stop | 0,065 x 106 |
Mission time | 20 y |
Handle module MGB-H-AA1A1-L-106619 (Order no. 106619) Mechanical values and environment
Housing material | Reinforced plastic, die-cast zinc nickel-plated, stainless steel |
Weight | |
Net | 1,00 kg |
Ambient temperature | -20 ... 55 °C |
Degree of protection | IP65 |
Installation orientation | Door hinge DIN left |
Other
Product version number | V3.0.0 |
Escape release MGB-E-A-100465 (Order no. 100465) Mechanical values and environment
Housing material | Die-cast zinc/stainless steel powder-coated |
Weight | |
Net | 0,75 kg |
Ambient temperature | -20 ... 55 °C |
Mechanical life | 1 x 106 |
Installation orientation | Any |
Other
Product version number | V2.0.0 |
Components 121244 Locking module MGB-L2-ARA-AM3A1-M-L-121244
- Guard locking with guard lock monitoring
- Can be connected in series with other AR devices (e.g. CES-AR and CET-AR)
- Emergency stop according to ISO 13850
- 2 pushbuttons (illuminated)
- With lens set, 6 pcs.
- With cable entry
- Unicode
106619 Handle module MGB-H-AA1A1-L-106619
- Intelligent bolt tongue
- Lockout bar
- Door handle
100465 Escape release MGB-E-A-100465
- Escape release from the danger zone
- Door handle signal red
- Extended actuation axis for thicker doors (available optionally)