Model | SZ-V32X*1 | ||
Type | Multi-bank Type | ||
Detection capability | Minimum detectable object size | Diameter: 20, 30, 40, 50, 70, 150 mm (depends on the setting), Reflectance: 1.8% min., Speed: 1.6 m/s max.*2 | |
Detectable angle | 190° (-5° to 185°) | ||
Response time (ON to OFF) | Standard Mode | Scan Cycle A | 160 ms (2 scans) to 1280 ms (16 scans)*3 |
Scan Cycle B | 168 ms (2 scans) to 1344 ms (16 scans)*3 | ||
Scan Cycle C | 176 ms (2 scans) to 1408 ms (16 scans)*3 | ||
High Speed Mode | Scan Cycle A | 80 ms (2 scans) to 640 ms (16 scans)*3 | |
Scan Cycle B | 84 ms (2 scans) to 672 ms (16 scans)*3 | ||
Scan Cycle C | 88 ms (2 scans) to 704 ms (16 scans)*3 | ||
Response time (OFF to ON) | Response time of ON to OFF + 150 ms | ||
Protection zone | Minimum detectable object size: 70 / 150 mm | Standard Mode: 8.4 m / High Speed Mode: 5.7 m | |
Minimum detectable object size: 50 mm | Standard Mode: 5.6 m / High Speed Mode: 3.8 m | ||
Minimum detectable object size: 40 mm | Standard Mode: 4.3 m / High Speed Mode: 2.9 m | ||
Minimum detectable object size: 30 mm | Standard Mode: 2.9 m / High Speed Mode: 2.0 m | ||
Minimum detectable object size: 20 mm | Standard Mode: 1.6 m / High Speed Mode: 1.1 m | ||
Warning zone | Minimum detectable object size: 70 / 150 mm | Standard Mode: 26 m / High Speed Mode: 23 m*4 | |
Minimum detectable object size: 50 mm | Standard Mode: 25 m / High Speed Mode: 21 m*4 | ||
Minimum detectable object size: 40 mm | Standard Mode: 24 m / High Speed Mode: 20 m*4 | ||
Minimum detectable object size: 30 mm | Standard Mode: 23 m / High Speed Mode: 18 m*4 | ||
Minimum detectable object size: 20 mm | Standard Mode: 21 m / High Speed Mode: 15 m*4 | ||
Additional safety distance | 100 mm*5 | ||
Maximum measurement distance | 60 m*6 | ||
Maximum number of banks | Max. 32 banks | ||
Multiple scanner heads | Max. 3 | ||
Camera | Monitor area: over 190° (-5° to 185°)*7 | ||
Display | QVGA 2.2 inch colour LCD | ||
Light source | Type, wavelength | Infrared laser diode, 905 nm | |
Laser class | IEC | Class 1 IEC / EN 60825-1 | |
FDA | Class 1 FDA 21 CFR 1040.10, 1040.11 (Laser Notice No.50)*8 | ||
JIS | Class 1 JIS C6802 | ||
Control output (OSSD output) | Output type | PNP or NPN transistor output (settings configurable with SZ-V Configurator) | |
Number of outputs | 2 outputs | ||
Max. load current | 500 mA*9 | ||
Residual voltage | Max. 2.5 V (with a cable length of 5 m) | ||
OFF-state voltage | Max. 2.0 V (with a cable length of 5 m) | ||
Leakage current | Max. 1 mA*10 | ||
Max. capacitive load | 2.2 µF (with a load resistance of 100 ?) | ||
Load wiring resistance | Max. 2.5 ? | ||
Input (safety-related) | PNP | ON-voltage: 10 to 30 V, OFF-voltage: Open or 0 to 3 V, Short-circuit current: Approx. 2.5 mA (EDM input: Approx. 10 mA) | |
NPN | ON-voltage: 0 to 3 V, OFF-voltage: Open or 10 V to Power voltage, Short-circuit current: Approx. 2.5 mA (Approx. 10 mA for EDM) | ||
Non safety-related output (AUX output) | Output type | Transistor output (PNP or NPN, settings configurable with SZ-V Configurator) | |
Number of outputs | 4 outputs | ||
Max. load current | 50 mA | ||
Residual voltage (during ON) | Max. 2.5 V (with a cable length of 5 m) | ||
Muting lamp | - | ||
Interface | USB | USB 2.0 | |
Ethernet | Standard | - | |
Transmission rate | |||
Cable | |||
Connector | |||
Networking/data output | |||
Cable length | Power cable | 30 m or less*11 | |
Connection cable | 20 m or less each*12 | ||
Ethernet cable | - | ||
Approved standards | EMC | EMS | IEC61496-1, EN61496-1, UL61496-1 (Type3 ESPE) |
EMI | EN55011 Class A, FCC Part15B Class A, ICES-003 Class A | ||
Safety | IEC61496-1, EN61496-1, UL61496-1 (Type3 ESPE), IEC61496-3, EN61496-3 (Type3 AOPDDR), IEC61508, EN61508, IEC62061, EN62061 (SIL2/SILCL2), EN ISO13849-1:2015 (PLd, Category3), IEC61784-3-3, UL508, UL1998, CSA C22.2 No.14, CSA C22.2 No.0.8 | ||
Rating | Power consumption | 11.8 W (without load), 55.0 W (with load)*13 | |
Power voltage | When using a converter power supply: 24 VDC ±10 %, Ripple (P-P) 10 % or less When using a battery: 24 VDC +20 % /-30 % | ||
Environmental resistance | Enclosure rating | IP65 (IEC60529) | |
Ambient light | Incandescent lamp: 1,500 lux or less*14 | ||
Operating ambient temperature | -10 to +50 °C (No freezing) | ||
Storage temperature | -25 to +60 °C (No freezing) | ||
Operating relative humidity | 35 to 85 % RH (No condensation) | ||
Storage relative humidity | 35 to 95 % RH | ||
Vibration resistance | 10 to 55 Hz, Double amplitude 0.7 mm, 20 sweeps in each of the X, Y, and Z directions | ||
Shock resistance | 100 m/s2 (Approx. 10 G), 16 ms pulse, 1,000 times in each of the X, Y, and Z directions | ||
Material | Scanner head | Main unit case | Magnesium |
Window | Polycarbonate, PEI | ||
Indicator part | Aluminum, PES*7 | ||
Display unit | case | Magnesium, PPS, Polycarbonate | |
System memory | Aluminum, PPE | ||
Weight | Approx. 2,100 g | ||
*1 Integrated models include display unit, scanner head, system memory and a connection cable (SZ-VS005). *2 If the object to be detected moves perpendicular to the detection plane, SZ-V cannot detect the object moving at speed over 1.6 m/s, regardless of the encoder setting. *3 The response time, protection zone, and warning zone are affected by the operation mode. *4 20% or more reflectance is necessary for the minimum detectable object in the warning zone. *5 If there is a highly reflective background within 1.5 m from the boundary of the protection zone, 200 mm must be added as supplementary necessary distance to the protection zone when calculating the minimum safety distance. *6 Even when using the network data output, the maximum measured output distance is 60 m. *7 Only applicable for the type with a camera. *8 The laser classification for FDA (CDRH) is implemented based on IEC60825-1 in accordance with the requirements of Laser Notice No.50. *9 The load current calculation of the OSSD output and AUX output is 1.5 A or less when using one scanner head, 1.0 A or less when using two scanner heads, and 0.5 A or less when using three scanner heads. *10 Includes when the power is OFF. *11 10 m or less when supplying power from a battery. *12 When supplying power from a battery, the length of each connection cable should be 10 m or less when using two scanner heads, and 5 m or less when using three scanner heads. *13 When using the SZ-V with series connected sensor heads, it is necessary to add 9.4 W per scanner head. Also, power consumption may temporarily be higher (maximum 3.6 W). Power consumption will be within the specification after SZ-V moves to normal operation. *14 An ambient light source should not be located within ±5° of the detection plane. |
The industrial spare part is crafted with precision to ensure your machinery operates at peak efficiency. Engineered for industrial products in demanding environments, it guarantees reduced downtime and increased productivity. components are built to withstand the toughest industrial conditions, making them essential for keeping your operations in the USA running smoothly.
Keyence offers a wide selection of industrial spare parts for different applications. Whether you’re performing maintenance or replacing worn-out parts, provides long-lasting, reliable solutions. Order your spare part today for fast delivery across the USA and keep your equipment performing at its best.
For industrial components and spare parts, trust Keyence to supply top-tier products that enhance the lifespan and efficiency of your machinery.
- Delivery of spare parts and industrial equipment throughout the USA by Fedex transport company.
- Flexible payment system accepting bank transfers, MasterCard, VISA, PayPall, App Pay, Google Pay.
- Directly from stock and on order.