Supply of spare parts for industrial enterprises in the USA

Polylux RTL

 RTL Polylux

Examine the Online Catalog of Industrial Supplies for Polylux


Great Offers at Unbeatable Prices
Great Offers at Unbeatable Prices
Discover incredible savings on industrial spare parts and components
Extensive Selection
Extensive Selection
Explore a wide variety of industrial spare parts to find the ideal fit for your needs
Quick Shipping
Quick Shipping
Get your industrial parts delivered promptly—right to your door!
Sale of any product from the catalog Polylux
RTL10
Price: On request
RTL100
Price: On request
RTL12.5
Price: On request
RTL16
Price: On request
RTL2.5
Price: On request
RTL20
Price: On request
RTL31.5
Price: On request
RTL4
Price: On request
RTL40
Price: On request
RTL5
Price: On request
RTL50
Price: On request
RTL6.3
Price: On request
RTL8
Price: On request
RTL80
Price: On request
Brand name
Polylux
tpl10.product.param.model
RTL
Country
Spain
ModelRTL2.5RTL4RTL5RTL6.3RTL8RTL10RTL12.5RTL16RTL20RTL25RTL31.5RTL40RTL50RTL63RTL80RTL100RTL125
Rated current2,5 A4 A5 A6,3 A8 A10 A12,5 A16 A20 A25 A31,5 A40 A50 A63 A80 A100 A125 A
Motor rating0,75 kW / 1 CV1,1 kW / 1,5 CV1,5 kW / 2 CV2,2 kW / 3 CV3 kW / 4 CV4 kW / 5,5 CV5,5 kW / 7,5 CV6,5 kW / 8,7 CV7,5 kW / 10 CV11 kW / 15 CV15 kW / 20 CV18,5 kW / 25 CV22 kW / 30 CV30 kW / 40 ºCV37 kW / 50 CV45 kW / 60 CV55 kW / 75 CV
Line voltage380 - 460 V380 - 460 V380 - 460 V380 - 460 V380 - 460 V380 - 460 V380 - 460 V380 - 460 V380 - 460 V380 - 460 V380 - 460 V380 - 460 V380 - 460 V380 - 460 V380 - 460 V380 - 460 V380 - 460 V
Reactor11,762 mH (50 Hz)7,351 mH (50 Hz)5,881 mH (50 Hz)4,667 mH (50 Hz)3,676 mH (50 Hz)2,941 mH (50 Hz)2,352 mH (50 Hz)1,838 mH (50 Hz)1,470 mH (50 Hz)1,176 mH (50 Hz)0,933 mH (50 Hz)0,735 mH (50 Hz)0,588 mH (50 Hz)0,467 mH (50 Hz)0,368 mH (50 Hz)0,294 mH (50 Hz)0,235 mH (50 Hz)
Voltage drop4% (50 Hz)4% (50 Hz)4% (50 Hz)4% (50 Hz)4% (50 Hz)4% (50 Hz)4% (50 Hz)4% (50 Hz)4% (50 Hz)4% (50 Hz)4% (50 Hz)4% (50 Hz)4% (50 Hz)4% (50 Hz)4% (50 Hz)4% (50 Hz)4% (50 Hz)
Thermal overload factor0,050,050,050,050,050,050,050,050,050,050,050,050,050,050,050,050,05
Frequency50/60 Hz50/60 Hz50/60 Hz50/60 Hz50/60 Hz50/60 Hz50/60 Hz50/60 Hz50/60 Hz50/60 Hz50/60 Hz50/60 Hz50/60 Hz50/60 Hz50/60 Hz50/60 Hz50/60 Hz
Protection degreeIP-20IP-20IP-20IP-20IP-20IP-20IP-20IP-20IP-20IP-20IP-20IP-20IP-20IP-20IP-20IP-20IP-20
CoolingANANANANANANANANANANANANANANANANAN
Ambient temperature40ºC40ºC40ºC40ºC40ºC40ºC40ºC40ºC40ºC40ºC40ºC40ºC40ºC40ºC40ºC40ºC40ºC
Temperature riseClass FClass FClass FClass FClass FClass FClass FClass FClass FClass FClass FClass FClass FClass FClass FClass FClass F
InsulationClass F - 155ºCClass F - 155ºCClass F - 155ºCClass F - 155ºCClass F - 155ºCClass F - 155ºCClass F - 155ºCClass F - 155ºCClass F - 155ºCClass F - 155ºCClass F - 155ºCClass F - 155ºCClass F - 155ºCClass F - 155ºCClass F - 155ºCClass F - 155ºCClass F - 155ºC
WindingsClass HC - 200 ºCClass HC - 200 ºCClass HC - 200 ºCClass HC - 200 ºCClass HC - 200 ºCClass HC - 200 ºCClass HC - 200 ºCClass HC - 200 ºCClass HC - 200 ºCClass HC - 200 ºCClass HC - 200 ºCClass HC - 200 ºCClass HC - 200 ºCClass HC - 200 ºCClass HC - 200 ºCClass HC - 200 ºCClass HC - 200 ºC
Test voltage3 kV (1 min, 50 Hz)3 kV (1 min, 50 Hz)3 kV (1 min, 50 Hz)3 kV (1 min, 50 Hz)3 kV (1 min, 50 Hz)3 kV (1 min, 50 Hz)3 kV (1 min, 50 Hz)3 kV (1 min, 50 Hz)3 kV (1 min, 50 Hz)3 kV (1 min, 50 Hz)3 kV (1 min, 50 Hz)3 kV (1 min, 50 Hz)3 kV (1 min, 50 Hz)3 kV (1 min, 50 Hz)3 kV (1 min, 50 Hz)3 kV (1 min, 50 Hz)3 kV (1 min, 50 Hz)
StandardsIEC/EN/UNE-EN 60076-6, CEIEC/EN/UNE-EN 60076-6, CEIEC/EN/UNE-EN 60076-6, CEIEC/EN/UNE-EN 60076-6, CEIEC/EN/UNE-EN 60076-6, CEIEC/EN/UNE-EN 60076-6, CEIEC/EN/UNE-EN 60076-6, CEIEC/EN/UNE-EN 60076-6, CEIEC/EN/UNE-EN 60076-6, CEIEC/EN/UNE-EN 60076-6, CEIEC/EN/UNE-EN 60076-6, CEIEC/EN/UNE-EN 60076-6, CEIEC/EN/UNE-EN 60076-6, CEIEC/EN/UNE-EN 60076-6, CEIEC/EN/UNE-EN 60076-6, CEIEC/EN/UNE-EN 60076-6, CEIEC/EN/UNE-EN 60076-6, CE
MountingScrewsScrewsScrewsScrewsScrewsScrewsScrewsScrewsScrewsScrewsScrewsScrewsScrewsScrewsScrewsScrewsScrews
IncludeBimetal thermal protectionBimetal thermal protectionBimetal thermal protectionBimetal thermal protectionBimetal thermal protectionBimetal thermal protectionBimetal thermal protectionBimetal thermal protectionBimetal thermal protectionBimetal thermal protectionBimetal thermal protectionBimetal thermal protectionBimetal thermal protectionBimetal thermal protectionBimetal thermal protectionBimetal thermal protectionBimetal thermal protection
Weight1,5 kg1,7 kg2 kg2,5 kg2,7 kg3,4 kg3,9 kg5,3 kg6 kg7,5 kg9,7 kg10,2 kg13,9 kg16,7 kg20,1 kg24,5 kg30,3 kg
Dimensions (AxBxCxDxE)135x145x108x125x102 mm 7Ø135x145x108x125x102 mm 7Ø135x145x108x125x102 mm 7Ø135x145x108x125x102 mm 7Ø135x145x108x125x102 mm 7Ø170x165x138x145x125 mm 7Ø170x165x138x145x125 mm 7Ø170x165x138x145x125 mm 7Ø210x198x185x178x173 mm 7Ø210x198x185x178x173 mm 7Ø210x198x185x178x173 mm 7Ø210x198x185x178x173 mm 7Ø280x190x205x80x250 mm 9Ø280x190x205x100x250 mm 9Ø280x190x205x115x250 mm 9Ø280x220x205x110x250 mm 9Ø340x220x255x106x310 mm 9Ø

Reactor

Advantages of resin technology:

  • Protection against corrosive environments
  • Protection against high vibration levels
  • Protection against electrodynamic efforts
  • Reduction of noise level
  • Increase of product's lifespan

​Safety class I

Includes thermal protection against overtemperatures

Possibility of tailor-made manufacturing

Technical remarks about the use of line reactors:

  • Reduction of the current harmonics generated by the equipment, reducing current consumption and improving power factor
  • Reduction of the peak factor of the current wave, increasing equipment's lifespan
  • Attenuation of the microcuts of the feeding voltage produced by the converter, source of the bad functioning of computers, robots and other equipments
  • Delivery of spare parts and industrial equipment throughout the USA by Fedex transport company.
  • Flexible payment system accepting bank transfers, MasterCard, VISA, PayPall, App Pay, Google Pay.
  • Directly from stock and on order.