Supply of spare parts for industrial enterprises in the USA

Polylux TIN

Transformer TIN Polylux

Examine the Online Catalog of Industrial Supplies for Polylux


Great Offers at Unbeatable Prices
Great Offers at Unbeatable Prices
Discover incredible savings on industrial spare parts and components
Extensive Selection
Extensive Selection
Explore a wide variety of industrial spare parts to find the ideal fit for your needs
Quick Shipping
Quick Shipping
Get your industrial parts delivered promptly—right to your door!
Sale of any product from the catalog Polylux
TIN1000A
Price: On request
TIN1200A
Price: On request
TIN1500A
Price: On request
TIN400A
Price: On request
TIN500A
Price: On request
TIN600A
Price: On request
TIN800A
Price: On request
Brand name
Polylux
tpl10.product.param.model
TIN
Country
Spain
tpl10.product.param.purpose
Transformer
ModelTIN400ATIN500ATIN600ATIN800ATIN1000ATIN1200ATIN1500A
LBL_INT_E400 A500 A600 A800 A1000 A1200 A1500 A
LBL_INT_S5 A5 A5 A5 A5 A5 A5 A
Class0,5 / 1 / 30,5 / 1 / 30,5 / 1 / 30,5 / 1 / 30,5 / 1 / 30,5 / 1 / 30,5 / 1 / 3
Rating1,5 VA / 3 VA / 10 VA2,5 VA / 5 VA / 15 VA2,5 VA / 5 VA / 17,5 VA3 VA / 7 VA / 18 VA5 VA / 9 VA / 20 VA6 VA / 11 VA / 24 VA8 VA / 17 VA / 30 VA
Frequency50 - 60 Hz50 - 60 Hz50 - 60 Hz50 - 60 Hz50 - 60 Hz50 - 60 Hz50 - 60 Hz
Thermic short circuit current40 IpN 1 seg.40 IpN 1 seg.20 In20 In20 In20 In20 In
Dynamic short circuit current2,5 I th 1 seg.2,5 I th 1 seg.2,5 I th 1 seg.2,5 I th 1 seg.2,5 I th 1 seg.2,5 I th 1 seg.2,5 I th 1 seg.
Permanent overloading120% Icth120% Icth120% Icth120% Icth120% Icth120% Icth120% Icth
InsulationIn air, Class EIn air, Class EIn air, Class EIn air, Class EIn air, Class EIn air, Class EIn air, Class E
Test voltage3kv (50Hz) 1 min.3kv (50Hz) 1 min.3kv (50Hz) 1 min.3kv (50Hz) 1 min.3kv (50Hz) 1 min.3kv (50Hz) 1 min.3kv (50Hz) 1 min.
Protection degreeIP30IP30IP30IP30IP30IP30IP30
Ambient temperature-20ºC a 40ºC-20ºC a 40ºC-20ºC a 40ºC-20ºC a 40ºC-20ºC a 40ºC-20ºC a 40ºC-20ºC a 40ºC
StandardsEN 60044-1EN 60044-1EN 60044-1EN 60044-1EN 60044-1EN 60044-1EN 60044-1
MountingScrewsScrewsScrewsScrewsScrewsScrewsScrews
Weight1,3 kg1,3 kg1,3 kg1,3 kg1,8 kg1,8 kg1,8 kg
Dimensions (AxBxCxDxE)114x50x145 mm114x50x145 mm114x50x145 mm144x50x185 mm144x50x185 mm144x50x185 mm144x50x185 mm

The short circuit on terminals or the connection to earth can be achieved by the double fast-on or connecting two wires on the same terminal.

Protection transformers

The C.T. when used as a current generator for protection relays has electrical characteristics which differ from those of the measuring transformer.

In fact, the measuring C.T. is expected to give a saturation of the magnetic circuit with 5P in primary currents, while in the case of protective C.T., it is necessary for the secondary current value to follow the increase in the primary current up to 10-15-20In, so as to guarantee the intervention of the relay in the case of unforeseen breakdown current.

It is important not to load the C.T. with a P performance which is greater than that indicated, so as not to modify the saturation value of the C.T.

P=R∗I2

P = Load on the C.T.

R = Resistance of the relay and resistance of the cables

I = Nominal secondary current of the C.T.

  • Delivery of spare parts and industrial equipment throughout the USA by Fedex transport company.
  • Flexible payment system accepting bank transfers, MasterCard, VISA, PayPall, App Pay, Google Pay.
  • Directly from stock and on order.