Examine the Online Catalog of Industrial Supplies for Schmersal
Performance Level, stop 0, up to | e |
Performance Level, stop 1, up to | d |
Category, Stop 0 | 4 |
Category, Stop 1 | 3 |
Diagnostic Coverage (DC) Level, Stop 0 | ≥ 99 % |
Diagnostic Coverage (DC) Level, Stop 1 | > 60 % |
PFH value, Stop 0 | 2.00 x 10⁻⁸ /h |
PFH value, Stop 1 | 2.00 x 10⁻⁷ /h |
Safety Integrity Level (SIL), Stop 0, suitable for applications in | 3 |
Safety Integrity Level (SIL), Stop 1, suitable for applications in | 2 |
Mission time | 20 Year(s) |
Common Cause Failure (CCF), minimum | 65 |
PFD value | 5.30 x 10⁻⁵ |
PFD value | 5.30 x 10⁻⁵ |
Mechanical life, minimum | 10,000,000 Operations |
Mounting | Snaps onto standard DIN rail to EN 60715 |
Terminal designations | IEC/EN 60947-1 |
Termination | rigid or flexible / Screw terminals M20 x 1.5 |
Cable section, minimum | 0.25 mm² |
Cable section, maximum | 2.5 mm² |
Tightening torque of Clips | 0.6 Nm |
Degree of protection of the enclosure | IP40 |
Degree of protection of the mounting space | IP54 |
Degree of protection of clips or terminals | IP20 |
Ambient temperature | -25 ... +60 °C |
Storage and transport temperature | -40 ... +85 °C |
Resistance to vibrations | 10 ... 55 Hz, Amplitude 0.35 mm |
Restistance to shock | 30 g / 11 ms |
Rated impulse withstand voltage Uimp | 4 kV |
Overvoltage category | III |
Degree of pollution | 2 |
Frequency range | 50 Hz / 60 Hz |
Operating voltage | 24 VAC -15 % / +10 %, 24 VDC -15 % / +20 % |
Ripple voltage | 10 % |
Rated operating voltage | 24 VAC |
Rated operating voltage | 24 VDC |
Rated AC voltage for controls, 50 Hz, minimum | 20.4 VAC |
Rated control voltage at AC 50 Hz, maximum | 26.4 VAC |
Rated AC voltage for controls, 60 Hz, minimum | 20.4 VAC |
Rated control voltage at AC 60 Hz, maximum | 26.4 VAC |
Rated AC voltage for controls at DC minimum | 20.4 VDC |
Rated control voltage at DC, maximum | 28.8 VDC |
Electrical power consumption | 3.2 W |
Electrical power consumption | 7.1 VA |
Contact resistance, maximum | 0.1 Ω |
Note (Contact resistance) | in new state |
Drop-out delay in case of power failure, typically | 80 ms |
Drop-out delay in case of emergency, typically | 30 ms |
Pull-in delay at automatic start, maximum, typically | 250 ms |
Pull-in delay at RESET, typically | 20 ms |
Material of the contacts, electrical | AgSn0, Ag-Ni, self-cleaning, positive drive |
This safety monitoring module relay offers advanced features for secure signal processing. It supports optional short-circuit recognition and includes a manual reset with edge detection in the fail-safe circuit. An automatic reset function is also available. It is designed for processing signals from contact sensors and outputs connected to potentials, such as safety light grids and curtains.
The relay includes three safety contacts for STOP 0 and two adjustable safety contacts for STOP 1 (with an adjustable delay from 1 to 30 seconds). It provides four signaling outputs and operates within a frequency range of 50 Hz to 60 Hz. The operating voltage ranges are 24 VAC (-15% / +10%) and 24 VDC (-15% / +20%), with a ripple voltage of 10%.
The device can withstand vibrations from 10 to 55 Hz with an amplitude of 0.35 mm and shocks up to 30 g for 11 ms.
- Delivery of spare parts and industrial equipment throughout the USA by Fedex transport company.
- Flexible payment system accepting bank transfers, MasterCard, VISA, PayPall, App Pay, Google Pay.
- Directly from stock and on order.