Examine the Online Catalog of Industrial Supplies for Schmersal
Standarde: | IEC 60947-5-3, EN ISO 13849-1, IEC 61508 |
Material of the housings:: | Plastic, glass-fibre reinforced thermoplastic, self-extinguishing |
Working principle: | inductive |
Recommended actuator: | MZM 120-B1.1 |
Switching distances to IEC 60947-5-3: - assured switching distance sao: - assured switch-off distance sar: |
0 mm 1 mm |
Protection class: | II x |
Switch-on time ED: | 100 % |
Response time: | < 150 ms |
Duration of risk: | < 150 ms |
Time to readiness: | < 4000 ms |
Series-wiring: | up to 31 devices |
Length of the sensor chain: | max. 200 m |
Cable length and cable section alter the voltage drop depending on the output current |
|
Mechanical data: | |
Execution of the electrical connection: | M12 connector plug, 8 poles |
Mechanical life: | ≥ 1.000.000 operations |
Notice - Mechanical life: | for safety guards ≤ 5 kg; actuating speed ≤ 0.5 m/s |
Resistance to shock: | 30 g / 11 ms |
Resistance to vibration: | 10 ... 150 Hz, amplitude 0,35 mm / 5 g |
Electrically ajdustable latching force (RE): | 30 N … 80 N |
Holding force Fmax: | 500 N |
Holding force F guaranteed: | 300 N |
Tightening torque for device fixing: | 8 N |
Ambient conditions: | |
Ambient temperature: | −25 °C … +55 °C |
Storage and transport temperature: | −25 °C … +85 °C |
Relative humidity: | 30% ... 95% |
- no condensation | |
- non-icing | |
Protection class: | IP67 / IP69K |
- Rated impulse withstand voltage Uimp: | 0,8 kV |
- Overvoltage category: | III |
- Degree of pollution: | 3 |
Electrical data: | |
Supply voltage UB (stabilised PELV units): | 20,4 V DC… 26,4 V DC |
Operating current: - Note |
max. 0.6 A plus current through the safety outputs |
Switching frequency: | 1 Hz |
Rated operating voltage Ue: | 24 VDC |
Rated insulation voltage Ui : | 32 VDC |
Rated operating current Ie: | 1 A |
No-load current Io: | max. 0.6 A |
Required short-circuit current: | 100 A |
Device fuse rating: | 2 A |
The Solenoid Interlock is a guard locking monitored connector plug designed for industrial applications. Crafted with a thermoplastic enclosure, The M12 8-pole connector facilitates seamless integration into existing systems.
Utilizing a power-to-lock mechanism, this solenoid interlock features a variably adjustable latching system, permitting displacement of the actuator and lock within specific tolerances – ± 5 mm vertically and ± 3 mm horizontally. The electronic contact-free, coded locking system enhances security.
Operational efficiency is bolstered by intelligent diagnosis and self-monitoring capabilities, which are essential for maintaining a reliable and safe working environment. Three LEDs provide a clear indication of operating conditions, ensuring visibility and facilitating quick assessments.
Designed for use as an end stop, this solenoid interlock employs an unlocking signal in the form of an enabling signal when closing and locking without force control.
- Delivery of spare parts and industrial equipment throughout the USA by Fedex transport company.
- Flexible payment system accepting bank transfers, MasterCard, VISA, PayPall, App Pay, Google Pay.
- Directly from stock and on order.