Examine the Online Catalog of Industrial Supplies for SENECA
POWER SUPPLY | 10..40 Vdc / 19..28 Vac |
POWER CONSUMPTION | 0,7 W |
ISOLATION | 1,5 kVac (6-way) |
STATUS INDICATORS | Power supply Error Dati transfer Data reception |
OPERATING TEMPERATURE | -20..+70°C (-20..+65°C UL) |
STORAGE TEMPERATURE | -20..+85°C |
RESOLUTION | 14 bit |
ACCURACY CLASS | 0,05 |
STABILITY | 0,04% |
LINEARITY | 0.025 % |
THERMAL DRIFT | < 50 ppm/K |
CONNECTIONS | Removable 4-way screw terminals, max. cross-section 1.5mm, pitch 3.5mm Micro USB on the front Rear connector IDC10 for DIN rail IEC EN 60715 |
MOUNTING | For 35 mm DIN 46277 rail |
DATA STORAGE | EEPROM for configuration parameters, retention time 10 years |
INTERFACES | RS485 2 wires Micro USB |
SPEED | Up to 115.200 bps |
PROTOCOLS | ModBUS RTU slave |
COMMUNICATION TIME | < 10 ms (@38.400 bps) |
MAX DISTANCE | Up to 1.200 m |
CONNECTIVITY | Max 32 nodes |
PROGRAMMING | Plug&play configuration (EASY SETUP) DIP switch System software (Z-NET4) Android app (EASY SETUP APP) |
PROGRAMMABLE PARAMETERS | Eight-level programmable filter for reading stabilization; 50 Hz or 60 Hz rejection; Floating-point, inverse floating-point, 16-bit fixed-point, tenths of a degree, tenths/hundredths of an ohm measurement; acquisition speed; reset value in the event of fault or freezing last reading; three-wire resistance compensation on mean value |
NUMBER OF INPUT CHANNELS | 4 |
TYPE OF INPUT CHANNELS | RTD with 2,3 or 4 wires cabling PT100, EN 60751/A2 (ITS-90), -200..+650°C PT500, EN 60751/A2 (ITS-90), -200..+750°C PT1000, EN 60751/A2 (ITS-90), -200..+210°C NI100, EN 60751/A2 (ITS-90), -60..+250°C |
HUMIDITY | 30..90% non-condensing |
PROTECTION DEGREE | IP20 |
WEIGHT | 140 g |
DIMENSION | 17.5x100x112 mm |
HOUSING | PA6 black color |
CERTIFICATIONS | CE, UL |
NORMS | EN 61000-6-4, EN 61000-6-2, EN 61010-1 |
Z-4RTD2 is a device designed to convert signals from platinum or nickel resistance temperature detectors (RTD) such as PT100, PT1000, PT500, Ni100, with 2, 3 or 4 wires. The device is compatible with power supplies ranging from 10 to 40 VDC or 19 to 28 VAC.
The Z-4RTD2 features a 4-channel input for RTD sensors, and can provide a resolution of either 14 bits or 13 bits depending on the input range. The device can be programmed via software EASY Setup, Z-NET4 or through DIP-switches. It also has a microUSB connector located on the front panel for easy connection.
The device is well-insulated with a 1.5 kVac 6-way insulation that separates each input channel, power supply, and communication. This ensures safety and reduces the risk of electrical interference and noise.
- Delivery of spare parts and industrial equipment throughout the USA by Fedex transport company.
- Flexible payment system accepting bank transfers, MasterCard, VISA, PayPall, App Pay, Google Pay.
- Directly from stock and on order.